Ethernet and PoE - for 19" RACK

DL-Cat.6A-M

Order number: A04196

LPZ 1 and higher, Ethernet without PoE

  • fine surge protection
  • installation at protected device inside LPZ1 and higher (not suitable for LPZ 0)
  • for pprotection of Ethernet networks (up to Cat.6A) without PoE
  • installation into DL-PL-RACK-1U box
  • DL-...-M with front output
  • DL-...-R-M with rear output
  • not applicable for Ethernet with PoE

Technical parameters

Parameter name Parameter value
Type of SPD C2,C3
Location of SPD ST 2+3
Mounting DL-PL-RACK-1U
Maximum operating voltage Uc 6.00 V AC
Maximum operating voltage Uc 8.50 V DC
Maximum operating voltage POE Uc 6.00 V AC
Maximum operating voltage POE Uc 8.50 V DC
Nominal load current per core at 25 °C IL 0.5 A
Treshold frequency core-core f 500.00 MHz
Insertion attenuation at treshhold frequency 2.90 dB
C2 nominal discharge current (8/20 µs) per core In 0.20 kA
C2 total discharge current (8/20 µs) cores-PE ITotal 1.60 kA
C2 voltage protection level mode (POE) at In Up 55.00 V
C2 voltage protection level mode core-PE at In Up 400 V
C2 voltage protection level mode core-core at In Up 55 V
C3 voltage protection level mode (POE) at 1 kV/µs 30.00 V
C3 voltage protection level mode core-PE at 1 kV/µs Up 600 V
C3 voltage protection level mode core-core at 1 kV/µs Up 30 V
Response time core-core ta 1 ns
Response time core-PE ta 100 ns
Connection (input - output) RJ 45/RJ 45
Degree of protection IP 20
Range of ambient temperatures (min/max) -40 / 80 °C
Humidity 5 - 95 %
According to standard EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
Customs tariff number 85363010
EAN 8595090541967

Files for download

  • Product dimensions

  • Basic circuit diagram