ST1 (HX)
HX-470-N50-F/M
Order number: A06556connectors N 50 Ohm
- lightning current arrester for coaxial line
- installation at the boundary of LPZ 0 and LPZ 1 zones at the line entry into building
- for protection of telecommunication equipment against impact of direct or indirect lightning strike
- suitable for the combined signal and power supply distribution
Technical parameters
Parameter name | Parameter value | |
---|---|---|
Type of SPD | D1,C2 | |
Location of SPD | ST 1+2 | |
Maximum operating voltage | Uc | 360.00 V DC |
Nominal load current | IL | 6.000 A |
Frequency range | f | 0,00 - 3000,00 MHz |
Impedance | Z | 50 Ω |
Power (CW) | P | 1 175.00 W |
Insertion loss typ. (max.) | A | 0,2 (0,4) dB |
VSWR typ. (max.) | VSWR | 1,1 (1,2) |
D1 impulse discharge current (10/350 µs) core-PE | Iimp | 2.50 kA |
C2 nominal discharge current (8/20 µs) core-PE | In | 10.00 kA |
Dynamic spark-over voltage at 1kV/µs | Udyn | 980.00 V |
Response time core-PE | ta | 100 ns |
Connection (input - output) | N 50 | |
Degree of protection | IP 66 | |
Range of ambient temperatures (min/max) | -40 / 80 °C | |
According to standard | EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012 | |
ETIM Class | EC001466 | |
Customs tariff number | 85363010 | |
EAN | 8595090565567 |