ICCP device

CP-40-BOX

Order number: A05346

SPD for Cathodic Corrosion Protection System

  • combines an AC current diverter and a SPD in one enclosure
  • AC diverter leads AC currents to earth, so it eliminates the negative influence of induced AC voltages on the protected steel pipe lines. AC corrosion currents can appear on the pipe lines installed in parallel to high voltage overhead lines.
  • SPD part protects the cathodic protection system against direct or indirect lighting strokes up to 100 kA (10/350 μs)
  • conducts AC currents up to 40 A to ground but doesn't affect the function of the cathodic protection system nor the leakage signal of 10 kHz
  • more CP-40 devices can be connected in parallel to reach higher current (80, 120 and more Amps)

Technical parameters

Parameter name Parameter value
Maximum continuous DC operating voltage (P-E) Umax 18 V
Maximum leakage current at Umax (P-E) IL 1.0 mA
Lightning impulse current Iimp 100.00 kA
Nominal discharge current (8/20 µs) In 100.00 kA
Maximum peak AC current 1 s / 50 Hz (P-E) Imax 400 A
Maximum continuous AC current 50 Hz (P-E) IA 40 A
100 : 1
Degree of protection IP 65
Range of ambient temperatures (min/max) -25 / 80 °C
Dimensions 300 x 300 x 170 mm
Mounting surface on the desk
Customs tariff number 85363030
EAN 8595090553465